Skip to the content.

IBM Rational Quality Manager (RQM) - Steps

Process steps in the Rational Quality Manager plug-in

Execute Test Case

Execute a test case.

Name Type Description Required
Adapter ID String The numeric ID or name of the adapter to use to run the test script in the test case. No
Execution Arguments String List of optional, blank space-separated arguments. The arguments can be as follows: 1. -exitOnComplete=< true or false >. if true, command will not exit until execution is completed or canceled. If false (default), command will exit immediately after triggering execution. 2. -printResultUrl= : If true the URL for the associated execution result will be logged. Note: For automated test case execution, this option also requires -exitOnComplete=true to be specified. 3. -variables=<var1Name:var1Value,var2Name:,va3Name:var3Value> : Specify Execution variable and optional values to be passed to execution. Note: Variable name and value are separated by colon :, if value is provided. No
Password Password The password to use when connecting to Rational Quality Manager. Yes
Project Area Name String The project area to use in Rational Quality Manager. Yes
RQM User String The user name to use when connecting to Rational Quality Manager. Yes
RQMExecutionTool.jar String Specify the folder or full path to the RQMExecutionTool.jar. RQM testing requires the RQMExecutionTool.jar that matches the installed RQM version. Yes
Repository URL String The repository URL of the Rational Quality Manager server. For example, https://hostname:9443/qm. Yes
Test Case Execution Record ID String The numeric ID of the test case execution record to run. Yes
Test Script ID String The numeric ID of the test script to run in the test case. No

Execute Test Suite

Execute a test suite.

Name Type Description Required
Adapter IDs String The numeric IDs or names of the adapters, separated by commas, to use to run the test scripts in the test suite. No
Execution Arguments String List of optional, blank space-separated arguments. The arguments can be as follows: 1. -exitOnComplete=< true or false >. if true, command will not exit until execution is completed or canceled. If false (default), command will exit immediately after triggering execution. 2. -printResultUrl= : If true the URL for the associated execution result will be logged. Note: For automated test case execution, this option also requires -exitOnComplete=true to be specified. 3. -variables=<var1Name:var1Value,var2Name:,va3Name:var3Value> : Specify Execution variable and optional values to be passed to execution. Note: Variable name and value are separated by colon :, if value is provided. No
Password Password The password to use when connecting to Rational Quality Manager. Yes
Project Area Name String The project area to use in Rational Quality Manager. Yes
RQM User String The user name to use when connecting to Rational Quality Manager. Yes
RQMExecutionTool.jar String Specify the folder or full path to the RQMExecutionTool.jar. RQM testing requires the RQMExecutionTool.jar that matches the installed RQM version. Yes
Repository URL String The repository URL of the Rational Quality Manager server. For example, https://hostname:9443/qm. Yes
Test Script IDs String The numeric IDs of the test scripts, separated by commas, that are steps in the test suite. No
Test Suite Execution Record ID String The numeric ID of the test suite execution record to run. Yes
Back to …   Latest Version IBM Rational Quality Manager (RQM)      